               Clause of the Unified  Provision  from  the Contents of the Clause     Remarks.
               Building Bye Laws   National Building  Code,
               2016               2016 (or earlier)
               9.31 Fire Escape   Part 4, Fire and Life safety  The route and enclosure to fire  Only valid for buildings
               Staircase          (most related)        escape shall be free of obstructions  as per Section 27 and 33
                                                        at all times, except a doorway  of the Delhi Fire Service
                                                        leading to the fire escape which shall  Rules,  2010  (Refer  9.3 of
                                                        have the required fire resistance.  the UBBL-2016)
                                                        Fire escape shall be constructed
                                                        of non-combustible materials of
                                                        required fire resistance  (refer NBC
                                                        Part 4). Unprotected  steel frame
                                                        staircase will not be accepted as fire
                                                        escape. The staircase enclosure if on
                                                        external  wall  of  the  building  shall
                                                        be ventilated to atmosphere at each
                                                        landing or in case it is in the core of
                                                        the building it shall be maintained
                                                        at a positive pressure as mentioned
                                                        in NBC part IV, Fire and Life Safety,
                                                        with both automatic and manual
                                                        operation facilities and fire alarm
                                                        systems.
               9.3.2 Pressurization of  Part 4: Fire and Life Safety.  For pressurization specifications of  -do-
               Staircases (Protected   (most related)   various  building  components  refer
               Escape Routes)                           NBC Chapter 4 Fire and Life Safety.



               10.1 Provisions and   Not specified, but maybe  The schemes/ projects formulated on the  Valid for all buildings of
               applicability of Green  suggesting  Part  11: basis of provisions given in Master plan/  plot size more than 105
               Buildings          Approach to Sustainability.  Zonal  Development  Plan  will  require  sq. m. (This excludes a
                                  (most related)        approval  as  indicated:  {Chapter  3  of  major chunk of plotted
                                                        these  Bye-Laws,  NBC  (latest),  ECBC  residential building stock
                                                        2007 or latest, BEE Star rating/ IGBC/  of Delhi)
                                                        GRIHA Certification} Provisions and
                                                        applicability for various plot sizes
                                                        (all use premises)
               11.3 Applicability   Part  3,  Section  13 For   additional   and   detailed  Accessibility clauses are
               of Provisions for   Development   Control requirements  other  than  specified  in  only applicable to Public
               Universal Design   Rules   And    General these  Unified  Building  bye-  Laws  Buildings.
               for Persons with   Building  Requirements: 2016,  the  Harmonized  Guidelines   Not applicable to private
               Disabilities, elderly   Requirements  For and  Space  Standards  for  Barrier  Free
               and Children       Accessibility  In  Built Built  Environment  for  Persons  with   plotted residences. Even
                                  Environment For Elders  Disability  and  Elderly  Persons  –   in Residential Group
                                  And    Persons   With February  2016  published  by  Ministry   Housing, it is valid only
                                  Disabilities          of Urban Development, Govt. of India   for common areas on the
                                                                                      ground level/stilts.
                                                        shall  be  followed  along  with  NBC
                                                        Chapter  3-Clause  13  Requirements
                                                        for  accessibility  in  Built  environment
                                                        for elders and persons with disabilities
                                                        and  Annex  B:  Anthropometrics  and
                                                        Requirements for Accessibility in Built-
                                                        Environment  for  Elders  and  Persons
                                                        with Disabilities.