CASE STUDIES


               Clause of the Unified  Provision  from  the Contents of the Clause     Remarks.
               Building Bye Laws   National Building  Code,
               2016               2016 (or earlier)
               8.4.6              Part 4, Fire and Life safety  The building shall be suitably  -do-
               Compartmentalisation (most related)      compartmentalized so that fire/
                                                        smoke remains confined to the area
                                                        where fire Incident has occurred and
                                                        does  not  spread  to  the  remaining
                                                        part of the building. All floors shall
                                                        be compartmented as per NBC
               8.4.7 Ramps        Part 4, Fire and Life safety  All  structural  design/safety -do-
                                  (most related)        aspects as per latest BIS Codes &
                                                        NBC, shall be complied along with
                                                        consideration  of weight of Fire
                                                        Engine & its manoeuvrings
                                                        Minimum size of the car lift shall be
                                                        as per NBC norms.
               8.4.9 h Glass Façade/   Part 4, Fire and Life safety  Service ducts and shafts shall be  -do-
               Service Ducts/Shafts/  (most related)    enclosed by walls and doors with
               Refuge Area/ Vents                       fire resistance rating (Refer NBC)
               8.5.2 Electrical   Part 4, Fire and Life  Separate circuits for water pumps,  -do-
               Services           safety and Part 8, Section  lifts, staircases and corridor lighting
                                  2: Electrical and  Allied  and blowers for pressurizing system
                                  Installations.   (most shall be provided directly from the
                                  related)              main switchgear panel (for detailed
                                                        specifications refer NBC).
               8.5.4 Air Conditioning Part 4, Fire and Life safety  The  air  filters  of  the  air-handling  -do-
                                  and Part 8; Section 3:  Air  units shall be of non-combustible
                                  Conditioning, Heating and  materials or fire rated (refer NBC)
                                  Mechanical  Ventilation.
                                  (most related)
               8.5.6 Gas Supply   Part 4, Fire and Life safety  For detailed information on gas  -do-
                                  and Part 9; Section 4: Gas  pipe installations, refer NBC.
                                  Supply (most related)
               8.10 General features   Part 4, Fire and Life  The lift lobby preventing stake and  -do-
               – free from FAR    safety and Part 8; Section  plume effect as per NBC norms and
               calculations (subject to  5: Installation  of Lifts,  as approved by the Fire Services,
               Fire Safety Clearance   Escalators and Moving  shall be free from FAR calculations.
               and other mandatory   Walks. (most related)  For size of lift lobby See 8.4.4. (a).
               clearances):