               Clause of the Unified  Provision  from  the Contents of the Clause     Remarks.
               Building Bye Laws   National Building  Code,
               2016               2016 (or earlier)
               9.2.4 Quality of   Part-V Building Materials  All material and workmanship  This  appears  to  be
               Materials and      and Part-VII          shall be of good quality conforming  universally applicable.
               Workmanship                              generally to accepted standards of
                                  Construction Practices and   Central  Public  Works  Department
                                  Safety
                                                        and  Indian  Standard  Specification
                                                        and  Codes  as included  in  Part-V
                                                        Building Materials and Part-VII
                                                        Construction Practices and Safety of
                                                        National Building Code of India.
               9.2.5 Control of Signs   Appears  to  be  Part No  advertising  signs  (including  This  only  talks
               (Hoardings) and    10,  Section  2:  Signs hoarding)  on  buildings  or  on  land  about  hoardings  for
               Outdoor Display    And   Outdoor  Display shall be displayed without the  advertising, but gives
               Structures.        Structures            prior approval of the Sanctioning  this specific provision a
                                                        Authority.  The  standards  specified  universal applicability.
                                                        in National Building Code of India
                                                        as amendments time to time shall be
                                                        applicable.
               9.3 Fire Safety    Part 4: Fire and Life Safety Rule 27 of Delhi Fire Service Rules  This  makes  Part  4:
                                                        shall be marked fire and life safety  Fire and Life Safety
                                                        measures as per the  National  valid only for Certain
                                                        Building Code of India concerning  Buildings  (High
                                                        minimum    standards  for  fire Rise) like Residential
                                                        prevention and fire protection as  buildings above 15 m,
                                                        covered under Rule 33 of the Delhi  educational, mercantile
                                                        Fire Service Rules            and institutional above
                                                                                      9m, etc., as per Rule 27 of
                                                                                      Delhi Fire Service Rules,
                                                                                      2010. This means it is not
                                                                                      universally applicable.
               9.3.2 Pressurization of  Part 4: Fire and Life Safety For pressurization specifications of  This  makes  Part  4:
               Staircases (Protected                    various  building  components  refer  Fire and Life Safety
               Escape Routes)                           NBC Chapter 4 Fire and Life Safety. valid only for Certain
                                                                                      Buildings      (High
                                                                                      Rise) like Residential
                                                                                      buildings above 15 m,
                                                                                      educational, mercantile
                                                                                      and institutional above
                                                                                      9m, etc., as per Rule 27 of
                                                                                      Delhi Fire Service Rules,
                                                                                      2010. This means it is not
                                                                                      universally applicable.