CASE STUDIES


               Clause of the Unified  Provision  from  the Contents of the Clause     Remarks.
               Building Bye Laws   National Building  Code,
               2016               2016 (or earlier)
               7.24 Special Provisions  Special  Provisions  for For Hospitals, Hotels & Banquets  This  is valid  for  all
               for Other Buildings   Other Buildings which are  Halls,  Stadiums,  Jails,  Court those buildings  which
               which are not covered  not  covered  under MPD  Complexes,  Art  Galleries, are not included in the
               under MPD and      and Building Bye Laws:  Museums, Filling Stations, Bus  Masterplan  Delhi  or
               Building Bye Laws                        Terminals/ Depot, Multi-storey  the  Unified  Building
                                                        Parking, Sports Complexes and any  Byelaws, which in fact
                                                        other special structures/ buildings,  cover most residential,
                                                        the provisions in the following  institutional  buildings,
                                                        documents shall apply:        hospitals etc.
                                                        a.  Development        Control
                                                           Regulations of MPD.
                                                        b.   National Building Code.
                                                        c.  Any other statutory provisions
                                                           of Republic of India.
                                                        d.  International  Guidelines  of
                                                           credential.
               7.28.3 Lifts and   No   specific  provision Mechanical Car Lift and Hoist: Shall
               Escalators         mentioned.            be as per relevant provisions of IS
                                                        codes/ National Building code/
                                                        manufacturer specifications
               Table 8.2 Note 2   No   specific  provision Ramps shall be counted as one  This clause is only valid
               Travel Distance for   mentioned.         of the means of escape wherever  for High Rise Buildings,
               Occupancy and Type                       permitted  in  National  Building  which  are  buildings
               of Construction                          Code.                         above 15 m height.
                                                                                      Most plotted residential
                                                                                      buildings  are  below
                                                                                      this height.  Therefore
                                                                                      all provisions are not
                                                                                      universal.
               8.4.5 h. Basements  Part  4:   Fire  and Mechanical extractors shall be  This recognises the Part 4
                                  Life    Safety,   and  designated to permit air changes  and Part 8 (Section 3) for
                                  Part    8:    Building per hour as required by NBC Part 4,  the purposes mentioned.
                                  Services; Section 3:  Air- Fire and Life Safety in case of fire or  This clause is only valid
                                  conditioning, Heating and  distress call. However, for normal  for High Rise Buildings,
                                  Mechanical Ventilation of  operation, air changes schedule  which  are  buildings
                                  National Building Code.  shall be as given in Part 8, Building  above 15 m height.
                                                        Services, Section 3, Air-conditioning,  Most plotted residential
                                                        Heating and Mechanical Ventilation  buildings  are  below
                                                        of National Building Code.    this height.  Therefore
                                                                                      all provisions are not
                                                                                      universal.