CASE STUDIES
Clause of the Unified Provision from the Contents of the Clause Remarks.
Building Bye Laws National Building Code,
2016 2016 (or earlier)
8.4.9 k Part V of the National Glass quality shall be as per IS This clause is only valid
Building Code, 2016 lists Codes given below in Table 8.3. for High Rise Buildings,
Glass Façade/ Service the IB codes that have which are buildings
Ducts/ Shafts/ Refuge been listed in the Unified 2553 (Part 1):1990 Specification for above 15 m height.
Area/ Vents safety glass: Part 1 General purpose
Buildings Bye Laws 2016. Most plotted residential
(third revision)
buildings are below
2835:1987 Specification for flat this height. Therefore
transparent sheet glass (third all provisions are not
revision) universal. This is because
the adoption is only for
438:1994 Specification for silvered the High Rise Buildings.
glass mirrors for general purposes
(second revision)
5437:1994 Specification for figured
rolled and wired glass (first
revision).
14900:2000 Specification for
transparent float glass.
16231:2014 (Part 4) Code of Practice
on use of Glass in Buildings – Safety
Related to Human Impact.
BIS Codes & National Building Code
of India concerning standards, as
amended from time to time; unless
otherwise specified in these bye –laws
shall be followed.
9.1 Structural Safety Part-VI structural design, The structural design of foundation, This appears to be
section-1 loads, section-2 masonry, timber, plain concrete, universally applicable.
foundation, section-3 reinforced concrete, pre-stressed
wood, section-4 masonry, concrete and structural steel shall
section-5 concrete and be carried out in accordance with
section-6 steel Part-VI structural design, section-1
loads, section-2 foundation,
section-3 wood, section-4 masonry,
section-5 concrete and section-6
steel of National Building Code
of India taking into consideration
all relevant standards prescribed
by Bureau of Indian Standards
including the standard given in
IS-Code 13920-2016, 4326-1993,
13828- 1993, 13827-1993, 13935-
1993, 456:2000, 800-1984, 801-1975,
875 (Part 2):1987, 875 (Part 3):1987,
875 (Part 4):1987, 875 (Part 5):1987,
883:1966, 1904:1987, 1905:1987,
2911 (Part 1): Section 1: 1979,
1893-2002 for general structural
safety, cyclone/wind protection,
Earthquake protection.