Page 93 - Shelter-October-2022
P. 93
CASE STUDIES
Clause of the Unified Provision from the Contents of the Clause Remarks.
Building Bye Laws National Building Code,
2016 2016 (or earlier)
Annexure VII 1: Part 6: Structural Safety In those areas where there are This is to be read with
Protection from no dangers of soil liquefaction Part 6 of Structural
Earthquakes or settlements or landslides, Safety which is already
all building structures and universally applicable.
infrastructures should be designed
using the relevant Indian Standards
as provided in the Building
Regulations and the National
Building Code
Annexure VII 2: Part 6: Structural Safety Buildings, structures and This is to be read with
Protection from infrastructures in the cyclone Part 6 of Structural
cyclonic wind damage prone areas should be designed Safety which is already
according to the Indian Standards universally applicable.
and Guidelines as provided in
the Regulations and the National
Building Code.
Annexure X: 3 b Part 8, section 3 Building The inside design conditions of a Energy Efficiency for
Provisions for Green Services HVAC conditioned space shall conform to HVAC, mandatory
Buildings- Energy National Building Code 2005 (Part only for Commercial
efficiency in HVAC 8, section 3) buildings.
The outside design conditions shall
conform to National Building Code
2005 (Part 8, section 3)
Chapter 2: g Service Service plans of building services This is as per the NBC
Plans such as plumbing, HVAC, Norms which have
installation of electrical fittings, etc., been otherwise made
as per NBC norms and standards mandatory.
are to be shown on the same scale as
that of the building plan.
Chapter 2: j Part III : Development Distance from Electric Lines: No The Part 3 is the general
Requirement of Site Control Rules And General verandah, balcony, or the like shall guidelines, or model
Building Requirements be allowed to be erected or any development guidelines.
additions or alterations made to a Making this mandatory
building within the space between will over rule all bye
the building and overhead electric laws.
supply line in accordance with the
Indian Electricity Rules (National
Electric Code 2011, Clause 3.2) and
its amendments from time to time
The distances provided in NBC
(Part III) are indicated.
7.4.13 Basement Part 4: Fire and Life Safety For basement of size more than This appears to be a
200sq.m. of BUA, the Fire Safety universally mandatory
measures as per NBC –Part 4 norms provision.
shall be followed.
*BUA- Built up area
October, 2022, Volume 23. No.2 - SHELTER 91